5 Commits
Author SHA1 Message Date
Zdeněk bb6815b9b2 ViaStitching 1.3: checks against poured copper, snap grid, skip markers
- clearances checked with exact shapes (round via) against pads, tracks,
  vias, copper drawings, other zones' poured copper and keepouts;
  Rectangular no longer uses square box tests
- Outline follows the poured copper edge, vias on the grid
- same-net pads: only thermal relief gap and hole-to-hole spacing
- optional zone refill before placing vias
- snap grid option (disables Grid Origin choice)
- via group mode: per net, per net and pattern, new group per run
- optional markers of skipped vias on User.Drawings with reason letter
- option to keep vias out of footprint references
- warning when "Only under selected Zone" has no zone of the net selected
- dialog: options in two columns, narrower window
2026-11-16 18:42:58 +01:00
Zdeněk ae5f101eda ViaStitching 1.2: KiCad 10 support, remember last values
- numeric KiCad version check (string compare broke on 10.x)
- GetBoardPolygonOutlines, PCB_VIA.GetWidth, PAD.GetEffectivePolygon: KiCad 10 API
- default grid 2.5 mm
- dialog values saved to ViaStitching.json in KiCad user settings dir
- net list: only nets with a zone, GND first and preselected
- add metadata.json
- README: KiCad 10
2026-11-15 10:23:11 +01:00
Zdeněk 46e744d886 ViaStitching 1.1: list available zones when target net has none, version in name 2026-11-15 09:23:05 +01:00
Zdeněk 0a8e177d05 CircularZone 2.0: layer selection, zone centered on selected pad 2026-11-15 09:23:05 +01:00
Zdeněk fa76f5e4e2 ViaStitching: don't load help bitmap by relative path in generated dialog
The plugin sets the bitmap with an absolute path after creating the dialog;
the relative path from the template only produced a 'can't open file' error.
2026-11-15 09:23:05 +01:00